°Cal-check PRO Catering Hand Held Precision Thermocouple Calibrator
Change Currency
- CAL PRO-Dairy(T or K): A unit for dairy food (+40°C)
- CAL PRO-Heldhot (T or K): A unit for held hot food (+63°C)
- CAL PRO-Cooking (T or K): A unit for central high temperature cook (+75°C)
- CAL PRO-Reheat (T or K): A unit for core reheated food (+82°C)
- CAL PRO-Hotfood (T or K): A set combining 3 units, one for held hot food(+63°C), one for central high temperature cook(+75°C) and one for core reheated food (+82°C)
- Accurate calibration of thermocouple instruments –better than +/-10uV
- Plug-in, press button & read – no PC needed
- No more need to send instruments away for calibration
- No wiring or range setting
- Readings with or without CJC
The °Cal-check PRO is a unique, novel concept for rapid, single point, plug-in thermocouple calibration with better than 10uV accuracy. No interconnection or setting up. Push button to select CJC included or excluded.
The compact, low cost device, terminated with miniature, male pins is simply plugged into the input port of the instrument. Comparison of the displayed reading is compared with the value stated on the °Cal-check label to indicate the accuracy of the test instrument with or without automatic ‘ cold junction compensation’.
The °Cal-check PRO is switched on after insertion and automatically switches off after 3 minutes resulting in a long battery life. If the checker is inadvertently left connected to the instrument, it will go into sleep mode to minimise power consumption. A LED indicates if the checker is operational or if the battery needs replacing; the checker will not produce a reading if the battery is ‘low’.
Specifications
General Description | The TCS50 °Cal-check is a unique, novel concept for rapid, simple and convenient in-house calibration of thermocouple instrumentation, eliminating the need to send it away for laboratory calibration |
---|---|
Type | Thermocouple Type K or T |
Accuracy | +/-0.25°C at 23°C ambient temperature |
Resolution | 0.1°C |
Host Instrument Input Impedance | 10k Ohm minimum |
Temperature Coefficient | 18-28°C ambient temperature, better than +/-0.5°C 0-50°C ambient temperature, +/-0.5 °C |
Storage Temperature Range | -20 to 70°C |
Ambient Operating Temperature | 0 to 50°C, 18 to 28°C recommended |
Power Consumption | Battery life: typically 2400 operations; 5 years’ shelf life |
Power Supply | CR2032; 3V 230mAh |
Standards Met | Thermocouple type: K or T to IEC584. Moulded Case rated IP50 |
Accessories | Supplied with a traceable certificate of calibration |