°Cal-check Catering Hand Held Precision Thermocouple Calibration Checker
Change Currency
CAL-Dairy -(T or K): A unit for dairy food (+40°C)
CAL-Heldhot -(T or K): A unit for held hot food (+63°C)
CAL-Cooking -(T or K): A unit for central high temperature cook (+75°C)
CAL-Reheat -(T or K): A unit for core reheated food (+82°C)
CAL-Hotfood -(T or K): A set combining 3 units, one for held hot food(+63°C), one for central high temperature cook(+75°C) and one for core reheated food (+82°C)
- Quick, accurate calibration checking of thermocouple instruments
- Plug-in, press button & read – no PC needed
- No more need to send instruments away for calibration
- No wiring or range setting –simple checking by anyone
- Food production & storage/ Dairy/ Brewing/ Ovens
The °Cal-check is a unique, novel concept for rapid, simple and convenient in-house calibration checking of thermocouple instrumentation, eliminating the need to send it away for laboratory calibration.
The compact, low cost device, terminated with miniature, male pins is simply plugged into the input port of the instrument. Comparison of the displayed reading is compared with the value stated on the °Cal-check label to indicate the accuracy of the test instrument.
The °Cal-check is switched on after insertion and automatically switches off after 60 seconds resulting in a long battery life. If the checker is inadvertently left connected to the instrument, it will go into sleep mode to minimise power consumption. A LED indicates if the checker is operational or if the battery needs replacing; the checker will not produce a reading if the battery is ‘low’.
Nine Type K & T thermocouple ranges are available to suit a wide range of applications including food production & storage, dairy and brewing processes and ovens.
Specifications
General Description | The °Cal-check is a unique, novel concept for rapid, simple and convenient in-house calibration checking of thermocouple instrumentation, eliminating the need to send it away for laboratory calibration. |
---|---|
Type | Thermocouple Type K or T |
Accuracy | +/-0.25°C at 23°C ambient temperature |
Resolution | 0.1°C |
Host Instrument Input Impedance | 10k Ohm minimum |
Temperature Coefficient | 18-28°C ambient temperature, better than +/-0.5°C 0-50°C ambient temperature, +/-0.5 °C |
Storage Temperature Range | -20 to 70°C |
Ambient Operating Temperature | 0 to 50°C, 18 to 28°C recommended |
Power Consumption | Battery life: typically 2400 operations; 5 years’ shelf life |
Power Supply | CR2032; 3V 230mAh |
Standards Met | Thermocouple type: K or T to IEC584. Moulded Case rated IP50 |
Accessories | Supplied with a traceable certificate of calibration |