Calibration Options

 

Traceable to ISO17025 (UKAS) calibration standards, Labfacility offer a choice of a 3 or 5 point traceable calibration using our in-house calibration facility, you can select any temperature points between -10°C & +200°C.

Please be aware that if you add a calibration option to your order, this will add 2-3 days lead time to your order.

 

What is Calibration?

Calibration of your measuring instruments has two objectives. It checks the accuracy of the instrument and it determines the traceability of the measurement. In practice, calibration also includes repair of the device if it is out of calibration. A report is provided by the calibration expert, which shows the error in measurements with the measuring device before and after the calibration.

Why is Calibration So Important?

Calibration defines the accuracy and quality of measurements recorded using a piece of equipment. Over time there is a tendency for results and accuracy to ‘drift’ particularly when using technologies or measuring parameters such as temperature and humidity. To be confident in the results being measured there is an ongoing need to maintain the calibration of equipment throughout its lifetime for reliable, accurate and repeatable measurements.

The goal of calibration is to minimise any measurement uncertainty by ensuring the accuracy of test equipment. Calibration quantifies and controls errors or uncertainties within measurement processes to an acceptable level.

Mineral Insulated Thermocouple probes available for calibration

 

 

 Mineral Insulated Thermocouple with Miniature Plug IEC - Types K,J,T,N

Mineral Insulated Thermocouple with Miniature Plug IEC - Types K,J,T,N

Various lengths available all terminated with an IEC miniature plug (220°C) for quick, simple connection.

Mineral Insulated Thermocouple with Standard Plug IEC - Types K,J,T,N

Mineral Insulated Thermocouple with Standard Plug IEC - Types K,J,T,N

Various lengths available all terminated with an IEC miniature plug (220°C) for quick, simple connection.

Fast Response (0.5mm diameter) Mineral Insulated Thermocouple with Threaded Pot & PFA IEC Tails - Type K

Fast Response Mineral Insulated Thermocouples IEC

Type K with threaded pot & tails in either 310 stainless steel or Inconel® Alloy 600 sheath.

Mineral Insulated Thermocouple with Plain Pot Seal and 1m of PFA Insulated IEC Lead - Types K,J,T,N

Mineral Insulated Thermocouple with Plain Pot Seal and 1m of PFA Insulated IEC Lead - Types K,J,T,N

Plain pot seal (200°C) with 1 Metre of PFA insulated lead, 7/0.2mm flat pair with tails or thermocouple connector.

 Mineral Insulated Thermocouple with Threaded Pot and100mm of PFA insulated Twin Twisted IEC lead - Types K,J,T,N

Mineral Insulated Thermocouple with Threaded Pot and 100mm of PFA insulated Twin Twisted IEC lead - Types K,J,T,N

Mineral insulated thermocouple in various lengths terminatied with 100mm,PFA insulated twin twisted IEC,7/0.2mm.

 Fast Response (0.5mm diameter) Mineral Insulated Thermocouple with Miniature IEC Plug - Type K

Fast Response (0.5mm diameter) Mineral Insulated Thermocouple with Miniature IEC Plug - Type K

Fast Response Mineral insulated thermocouple in type K. Various lengths available terminating with an IEC miniature plug (220°C) for quick, simple connection.

 

 Labfacility also offer the option of a 'system calibration', which involves 1 or 2 temperature probes and an instrument.

 

Bench Top & Panel Mount Instrumentation


Bench top instruments, some which work in conjunction with a PC, that can provide accurate monitoring of your application. Thermocouple and Pt100 options available.

Digital Thermometers


A large selection of digital thermometers including the Master Class Folding Cooking Thermometer, GM1311, GM1312 general purpose digital themometer, Therma1, Therma Plus waterproof, Therma differential, Therma Hygrometer and Digitron range.
L200 8-channel data Logger RTD Thermometer (dual input) Model CHY 804U

 

 

Calibration Type


Probes Required for

'Simulated Calibration'

 

Probes Required for

'System Calibration'

 

3 points (single channel)

fixed @ 0, 100, 200°C

0 1

3 points (dual channel)

fixed @ 0, 100, 200°C

0 2

5 points (single channel)

fixed @ 0, 50, 100, 150, 200°C

0 1

5 points (dual channel)

fixed @ 0, 50, 100, 150, 200°C

0 2